9100H-9120H

ABOUT PRODUCT

9100H – Normally Closed, Energised To Open, 9120H – Normally Open, Energised To Close.

Size

3/8"(10mm) & 3"(75mm)

End Connection

Std.-G-ISO-228 (BSP-F), Optional-NPT.

Body Material

SS ASTM A351 Gr.CF8/CF8M.

Differential Pressure

2 to 24 bar

Coil voltage

Standard -230, 110, 48, 24 V- 50 Hz. Optional – 24,110, 240 V DC & AC 50Hz or 60Hz.

Coil Rating

Continuously rated.

Fluids

Air, Water, Gas , light oil, Heavy oil

Application

Chemical, Textile, cement machinery, combustion equipments, air dryer, cleaning equipment and others.Not suitable for steam.

Seat

Standard – Nitrile (Buna ‘N’) Optional – Neoprene, Viton, EPDM

Temperature of Fluid

' -5°C to 120°C

Coil Insulation & Temperature

Class ‘H’ insulated upto 155°C.

Enclosure

Standard-General purpose IP-20, Optional-Weatherproof- RD-WP-67, Flameproof-RD-FLP-IIC + WP67.

Optional Feature

Mounting Bracket.

Sales Point

Most reliable, maintenance free, on-off valve in our range.

Note

1) Use of filter in the inlet size is highly recommended., 2) Not suitable for back pressure from outlet side.

Technical Data